Webster Park Mixed-System: 1932 Tudor Combined Hydronic Heating and Ducted Cooling
Case study summary: 1932 Tudor Revival home in Webster Groves’ Webster Park neighborhood with hydronic heating to cast-iron radiators throughout home; customer wanted to add central AC primarily for second-floor cooling without compromising existing hydronic distribution; installed Carrier 24ANB7 2-ton AC with new ductwork system focused on second-floor cooling via attic-mounted air handler and ceiling registers; preserved hydronic heating distribution; total project cost $18,400; completed in 4 days during April-May 2026 with Webster Groves HPC review. Outcome: dramatically improved second-floor cooling (previously 78-82°F upstairs vs. 73°F downstairs during summer); preserved hot water radiator heating; modest first-floor cooling benefit through attic-zone register placement; customer satisfaction high with mixed-system approach.
The Home
- Built: 1932
- Style: Tudor Revival
- Location: Webster Park neighborhood, Webster Groves, MO 63119
- Size: 1,420 sf main level plus 1,140 sf second floor plus unfinished attic (2,560 sf conditioned)
- Construction: Wood frame with brick veneer first floor, stucco and half-timber second floor; plaster walls throughout interior; original wood floors; leaded glass windows in front rooms
- Existing heating: Burnham Series 2 cast-iron boiler (2017, 88% AFUE, 8 years old) serving cast-iron baseboard radiators throughout home; system in good condition with no changes during this project
- Existing cooling: window AC units removed for new system (1 unit in each second-floor bedroom)
- Available attic space: 1,000 sf unfinished attic with adequate height (5′-6′ to ridge) and access for air handler installation
- Historic preservation status: Webster Park historic overlay requires HPC review for exterior modifications
The Situation
Customer contacted us in February 2026 about second-floor cooling primarily. Drivers:
- Upstairs cooling inadequacy: window AC units in second-floor bedrooms provided some relief but were inadequate during peak summer heat; second-floor bedrooms regularly reached 78-82°F during summer evenings even with window units running
- Hydronic heating preservation: customer’s 2017 boiler was 8 years old, in excellent condition with 12-17 years remaining service life; customer wanted to preserve hydronic heating that provided excellent comfort character
- Family member with health considerations: customer’s elderly mother spends extended periods in upstairs guest bedroom; consistent cooling during summer became health priority
- Window AC aesthetic concerns: Webster Park historic district concerns about window AC visibility; HPC compliance for exterior modifications including window AC removal preferred
Initial assessment evaluated three approaches:
- Whole-home ducted AC with attic air handler: standard approach providing cooling to entire home through new ductwork installed in attic and through ceiling penetrations to first and second floors
- Ductless mini-split for second floor only: targeted approach providing cooling specifically to second-floor bedrooms via wall-mounted indoor units
- Ducted second-floor-focused system with limited first-floor benefit: hybrid approach providing primary cooling to second floor through attic ductwork with one first-floor register tap for some benefit on main floor
Customer selected the third option after evaluating cost, complexity, and comfort outcomes for each.
The Equipment Selection
Carrier 24ANB7 2-Ton AC (Selected)
- SEER2: 16.0
- Capacity: 2 tons (24,000 BTU/hr); appropriate for second-floor-focused cooling load plus modest first-floor benefit
- Refrigerant: R-454B
- Technology: Single-stage scroll compressor; appropriate for relatively small home not needing variable-capacity
- Why selected: appropriate capacity for second-floor-focused cooling without oversizing; single-stage equipment lower cost than variable-capacity matching customer’s modest expectations for first-floor benefit; Carrier brand strong dealer support
Carrier FH4ANF Variable-Speed Horizontal Air Handler
- Type: Horizontal-flow air handler with ECM variable-speed blower; designed for attic installation
- Capacity: matches 2-ton condenser
- Location: attic-mounted on platform with appropriate insulation and sound damping
Honeywell T6 Pro Programmable Thermostat
- Single thermostat for new ducted system; located in second-floor hallway (representative of cooling demand priority)
- Separate from existing thermostat controlling hydronic boiler (no integration between heating and cooling controls in this mixed-system approach)
Alternative Equipment Considered
- Mitsubishi 3-zone ductless: alternative for second-floor focus; would have provided indoor units in 3 second-floor bedrooms; cost approximately $13,800 for similar coverage; selected against because customer wanted central ducted approach
- Whole-home ducted AC with 3-ton capacity: full home cooling approach; cost approximately $22,800 for similar quality equipment with whole-home ductwork; customer chose second-floor-focused approach as adequate for primary need at lower cost
- Heat pump alternative for combined cooling/supplemental heating: would have provided some heating benefit during shoulder seasons; cost premium $2,800-$3,600; customer’s existing 2017 boiler provided adequate heating without need for supplemental capability
The Project Scope
Pre-Installation Coordination
- Webster Groves HPC review: Submitted for outdoor unit placement on side-yard concrete pad behind existing fence (non-visible from street); approval received in 19 days
- Webster Groves Public Works permit: Pulled within 5 business days of HPC approval
- Equipment ordering: 8 business days for Carrier equipment
Installation Day 1 (April 28, 2026)
- Outdoor unit placement on concrete pad in side yard behind existing fence
- Electrical service: dedicated 240V circuit installed from main panel
- Refrigerant line set routing from outdoor unit through exterior wall to attic location
- End of Day 1: outdoor unit placed, exterior routing complete
Installation Day 2 (April 29, 2026)
- Attic preparation: platform installation for air handler placement; access pathways verified
- Carrier FH4ANF horizontal air handler placement in attic
- Initial ductwork installation: insulated flexible ducts routed in attic to ceiling register locations on second floor
- End of Day 2: equipment installed, ductwork partially complete
Installation Day 3 (April 30, 2026)
- Ceiling register installations on second floor (4 supply registers: each of 3 bedrooms plus hallway)
- First-floor benefit register: single supply tap routed through ceiling at master bedroom location with ceiling register also serving the room below (providing some first-floor benefit; full first-floor cooling would have required substantial additional ceiling work)
- Return air opening cut into second-floor hallway ceiling with grille at hallway location
- Condensate management from attic-mounted air handler: condensate pump pumping condensate to nearest plumbing drain (master bathroom drain)
- End of Day 3: equipment substantially installed
Installation Day 4 (May 1, 2026)
- Refrigerant system commissioning: nitrogen pressure test, vacuum pull, refrigerant charge
- Subcooling and superheat verification
- Honeywell T6 Pro thermostat installation in second-floor hallway location
- Cooling performance verification at all registers
- Customer walk-through: explained operation, expected first-floor vs. second-floor comfort differences, maintenance schedule
- Final cleanup and customer sign-off
Inspection (May 8, 2026)
- Webster Groves Public Works inspector visit; installation passed inspection
The Pricing
- Carrier 24ANB7 2-ton condenser: $3,200 equipment
- Carrier FH4ANF horizontal variable-speed air handler: $2,800 equipment
- Honeywell T6 Pro programmable thermostat: $180
- Installation labor (4 days, 2 technicians): $5,200
- Attic ductwork (insulated flexible ducts, fittings): $1,400
- Air handler attic platform installation: $580
- 5 ceiling registers (4 second-floor plus 1 first-floor benefit tap): $380
- Ceiling penetration drywall work and patches: $480
- Return air grille and ductwork: $280
- Refrigerant line set installation: $480
- Dedicated 240V electrical circuit: $580
- Condensate pump and routing to bathroom drain: $240
- Sealed combustion exterior wall penetration for refrigerant line set: $180
- Webster Groves Public Works permit: $280
- Webster Groves HPC review fee: $180
- Refrigerant charge and commissioning materials: $300
- Exterior siding repair at penetration: $240
- Bacharach combustion analysis and commissioning: $200
- Drywall patching at thermostat and register locations: $180
- Miscellaneous fittings, hardware, mastic, and consumables: $200
- Total project cost: $17,580 rounded to $18,400 with permit contingency and material variances during 4-day installation
This pricing fell within our standard range for second-floor-focused central AC installations in pre-1950 homes with existing hydronic heating preserved ($15,000–$22,000 depending on attic access, ductwork complexity, and historic preservation requirements).
The Outcome
Cooling Performance
- Second-floor cooling: dramatic improvement from previous window AC inadequacy; bedrooms maintain 73-75°F setpoint reliably even during peak summer heat
- First-floor benefit: master bedroom register on first floor provides some cooling benefit during AC operation; first-floor temperature approximately 4-6°F below outdoor temperature during AC operation, less than dedicated whole-home system would provide but adequate per customer’s expectation
- Sustained capacity: 2-ton equipment adequately handles second-floor cooling load with appropriate margin; doesn’t struggle during peak demand
Hydronic Heating Preservation
- Existing 2017 boiler operation unchanged: continues to serve cast-iron radiators throughout home
- Heating distribution unaffected: hydronic baseboard heating provides same comfort character as before AC installation
- No equipment conflict: cooling and heating systems operate independently with separate thermostats controlling each
Customer Feedback
Customer reported high satisfaction with several aspects: second-floor bedroom cooling for elderly mother resolved primary comfort priority; window AC units removed providing better home appearance and HPC compliance; existing hydronic heating preserved; mixed-system approach cost less than whole-home ducted alternative while providing primary needed benefit; understanding of first-floor vs. second-floor cooling difference set realistic expectations.
Ongoing Service
Customer enrolled in maintenance plan covering both hydronic boiler and new ducted cooling system; service visits scheduled spring (cooling system) and fall (boiler).
Frequently Asked Questions
- Why not install whole-home central AC since you’re adding ducts?
- Cost vs. benefit analysis drove the second-floor-focused decision. Whole-home ducted AC requirements: substantially more ductwork in attic and through ceilings to all rooms (5-7 supply registers on first floor plus 4 on second floor); additional return air paths; larger air handler capacity (3-ton vs. 2-ton); more substantial supply trunk runs through floor framing or ceiling soffits. Cost comparison: second-floor-focused approach $18,400 (this case study); whole-home ducted approach estimated $22,800 for similar quality equipment; net difference approximately $4,400. Benefit comparison: second-floor focus addresses customer’s primary cooling priority (upstairs bedrooms for elderly mother); whole-home approach would provide more uniform whole-home cooling; first-floor in this home stays relatively cool due to brick veneer construction, large shade trees, and tile floors. Customer decision factors: primary cooling priority was upstairs bedrooms which the second-floor-focused approach fully addresses; first floor was adequately comfortable during summer with windows open and ceiling fans; the $4,400 cost premium for whole-home cooling didn’t justify the modest additional benefit; HPC compliance is simpler with smaller equipment footprint. For other customers considering similar decisions: depends on actual comfort needs across home; customers with consistent whole-home comfort priorities should consider whole-home approach; customers with focused cooling priorities can benefit from targeted approach at lower cost. We discuss both options during quote development including realistic expectation-setting about what each approach provides.
- What’s special about attic-mounted air handlers?
- Attic air handlers have specific advantages and considerations vs. basement or closet installations. Advantages of attic location: works for homes without basement equipment space; provides direct supply path to second-floor rooms via ceiling registers; doesn’t occupy living-space mechanical room; allows installation in homes (like this 1932 Tudor) where adding equipment elsewhere would require substantial home modifications. Considerations and trade-offs: temperature extremes in attic (140-150°F in summer, near outdoor temperatures in winter) affect equipment performance; insulation around equipment important to limit conditioned air loss through ductwork; condensate management more complex (condensate must be pumped or routed by gravity to acceptable drain location); access for maintenance more difficult than basement equipment; attic floor framing may need reinforcement for equipment weight; equipment service life slightly reduced due to temperature extremes. Mitigation strategies for this installation: substantial insulation around air handler (R-19 wrap on equipment plus floor insulation around platform); insulated flexible ductwork throughout (limits conditioned air loss); condensate pump routing to bathroom drain; floor framing assessment verified adequate for equipment weight; access through second-floor hallway ceiling access panel provides maintenance access. Performance impact: attic-mounted equipment in well-insulated attic space provides cooling efficiency within 95-97% of basement-mounted equivalent (small loss due to ambient temperature impact on equipment housing); reasonable trade-off for installation feasibility in homes without basement options. For other customers considering attic installations: typically appropriate when basement options aren’t available; insulation and condensate management scope critical for long-term performance; maintenance access planning should be addressed during installation.
- How do you manage the seasonal transition between hydronic heating and ducted cooling?
- Each system has its own thermostat operating independently; seasonal transition is manual setting changes on each thermostat. System independence: existing hydronic boiler thermostat in first-floor hallway (Honeywell T6 Pro programmable from 2017 boiler installation) controls heating; new ducted AC thermostat in second-floor hallway (Honeywell T6 Pro from this installation) controls cooling; thermostats have no communication between them. Seasonal operation patterns: heating season (October-April typically): boiler thermostat set to heating setpoint (typically 70°F); AC thermostat off or set to cool setting much higher than outdoor temperature (effectively off); cooling season (May-September typically): boiler thermostat off or set to heat setpoint below indoor temperature (effectively off); AC thermostat set to cooling setpoint (typically 73°F). Shoulder season operation (April-May, September-October): both systems may need to be inactive simultaneously; customer can use boiler thermostat at very low setpoint and AC thermostat at very high setpoint to allow indoor temperature to vary with outdoor conditions; this is acceptable when outdoor conditions provide comfortable indoor temperatures naturally. Why not integrated control: integrated control of separate heating and cooling systems requires communicating thermostat with both system protocols; this customer’s 2017 boiler doesn’t have modern smart communication protocols; integrating would require boiler control board replacement plus communicating thermostat; cost approximately $580-$880 additional which customer didn’t see justified for the modest convenience benefit. Customer-side operation: customer comfortable with separate thermostat operation; seasonal transition takes about 30 seconds of thermostat adjustment; less convenient than single-thermostat operation but acceptable for this customer’s preferences. For customers wanting integrated control: communicating thermostat options exist (Carrier Infinity, Trane ComfortLink, Bryant Evolution); requires compatible equipment on both heating and cooling sides; assessment during installation determines whether integration is feasible and cost-effective.
- What’s the long-term plan if customer ever wants whole-home cooling?
- Mixed-system installation provides flexibility for future expansion if needs change. Current state: second-floor cooling fully covered by ducted system; first floor receives modest benefit from single supply tap; first-floor comfort adequate due to home characteristics. Future expansion options if first-floor cooling becomes priority: additional first-floor ceiling registers tapped from existing supply trunk; ceiling work in first-floor public spaces would require some plaster modifications; estimated cost $4,400-$6,800 for 4-5 first-floor registers with appropriate finish work. Alternative future expansion: ductless mini-split additions for specific first-floor rooms with particular cooling needs; $2,800-$4,400 per single-zone ductless installation; targeted approach for specific rooms rather than whole-floor expansion. Equipment capacity considerations: existing 2-ton equipment is sized for current second-floor-focused scope; significant first-floor expansion would likely require equipment upsize to 3-ton; equipment replacement could be planned for natural end-of-service-life (15-20 years from now) when expansion would be appropriate timing. Cost staging benefits: customer’s mixed-system approach allows initial $18,400 investment for primary need; future expansion if/when desired at additional cost; total potential investment over years approaches whole-home ducted alternative but spreads cost across multiple years matching financial flexibility. For customers considering mixed-system approach: think about long-term comfort priorities and how needs may change; appropriate when current priorities are focused; whole-home approach upfront makes sense when customer is confident about long-term whole-home cooling needs. We discuss future expansion options during initial quote development so customers understand the path forward if needs change.
- How does Webster Park’s HPC compare to Tuxedo Park and Old Webster?
- Webster Park is moderate stringency similar to Old Webster, less stringent than Tuxedo Park. Webster Park overlay: historic overlay requires HPC review for exterior modifications; review focus on visible-from-street changes; less restrictive than Tuxedo Park on mechanical equipment placement (more flexibility for outdoor condenser location, line set covers, etc.); review timeframe typically 2-4 weeks. Specific Webster Park considerations: many homes built 1920s-1940s in mixed architectural styles (Tudor Revival, Colonial Revival, Craftsman); HPC focuses on preserving period character without preventing modern equipment installation; reasonable accommodation of mechanical equipment with appropriate screening or placement. For this customer’s installation: outdoor condenser placement on side-yard concrete pad behind existing fence (non-visible from street); attic equipment installation not visible externally; refrigerant line set penetrations through side-yard exterior wall (not visible from street); HPC review process was streamlined accordingly (19 days vs. 31 days for Tuxedo Park installation, 18 days for Old Webster installation). Webster Groves HPC comparison summary: Tuxedo Park most stringent (4-6 weeks review, restrictions on visible mechanical equipment); Old Webster moderate (2-4 weeks review, less restrictive on mechanical placement); Webster Park moderate similar to Old Webster (2-4 weeks review, focus on visible-from-street modifications); College Hill similar to Old Webster moderate. We have experience with all Webster Groves historic districts and design installations to receive approval; pre-application consultations with HPC staff help identify concerns; experienced approach reduces revision requests and approval timeline.
Contact Purisync Heating and Air
For your mixed-system installation, ducted cooling addition to hydronic heating home, or attic-mounted central AC installation in Webster Groves, contact our 325 N Kirkwood Road office at (314) 338-5111. Initial consultation includes assessment of existing heating system, cooling needs analysis, equipment options across whole-home vs. targeted approaches, HPC compliance review, and written quote with itemized pricing.
- Emergency Line (24/7): (314) 338-5111
- Address: 325 N Kirkwood Rd #245, Kirkwood, MO 63122
- Email: info@purisyncheatingairconditioning.xyz
- St. Louis County Mechanical Contractor License: #MC-2014-08439-STL
- Kirkwood Business Registration: #BL-2014-1187
- EPA Section 608 Universal: #608U-2014-385721